Material Specifications
- FLANGE : I CASTING, A 395
- PFA LINING : ASTM D3307
- FEP LINING : ASTMD 2116, TYPE IV
Test & Inspection Data
- RESINS ARE CONFIRMING TO THE REQUIREMENTS OF ASTM F1545-97 (2003)
- HYDRAULIC TEST : 29 KG/CM2 AFTER LINING
- SPARK TEST : 15 KV D.C AFTER LINING
NB1 | NB2 | A | LINING THICKNESS (mm) |
40 | 25 | 107 | 3.8 |
50 | 25 | 120 | 3.8 |
50 | 40 | 120 | 3.8 |
80 | 25 | 144.5 | 4 |
80 | 40 | 144.5 | 4 |
80 | 50 | 144.5 | 4 |
100 | 25 | 170.5 | 4.5 |
100 | 40 | 170.5 | 4.5 |
100 | 50 | 170.5 | 4.5 |
100 | 80 | 170.5 | 4.5 |
150 | 25 | 221 | 5 |
150 | 40 | 221 | 5 |
150 | 50 | 221 | 5 |
150 | 80 | 221 | 5 |
150 | 100 | 221 | 5 |
NB1 | NB2 | A | LINING THICKNESS (mm) |
40 | 25 | 107 | 3.8 |
50 | 25 | 120 | 3.8 |
50 | 40 | 120 | 3.8 |
80 | 25 | 144.5 | 4 |
80 | 40 | 144.5 | 4 |
80 | 50 | 144.5 | 4 |
100 | 25 | 170.5 | 4.5 |
100 | 40 | 170.5 | 4.5 |
100 | 50 | 170.5 | 4.5 |
100 | 80 | 170.5 | 4.5 |
150 | 25 | 221 | 5 |
150 | 40 | 221 | 5 |
150 | 50 | 221 | 5 |
150 | 80 | 221 | 5 |
150 | 100 | 221 | 5 |